 Catalog 1308242 Issued 3-03
PRODUCTS UNLIMITED
Model 96 - 3100 series
Definite Purpose Contactor 1- or 2-pole, 20-40 FLA AC Coil
File E75492 File EN60947-4-1:1991 IEC 947-4-1
Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application.
Features
* Robust 1- and 2-pole contactors. * Shunt available on 1-pole models. * Convenient mounting plate.
Environmental Data
Temperature Range: Storage and Operating: -40C - +65C. Flammability: UL 94-HB housing.
Mechanical Data Contact Data @ 25C
Arrangements: 1 Form X (SPST-NO-DM) with or without shunt and 2 Form X (DPST-NO-DM). Maximum Ratings: See Contact Ratings Table. Material: Silver Cadmium Oxide. Contact Termination: 20, 25, 30 FLA Models Type: #10-32 Screw with quad 0.250" (6.35 mm) quick connects. Wire Size: 16-8 AWG (Stranding must be split for 8 AWG wire.) Tightening Torque: 25 in.-lbs. 40 FLA Models Type: Box Lug with dual 0.250" (6.35 mm) quick connects. Wire Size: 14-4 Cu/Al AWG Tightening Torque: 40 in.-lbs. Coil Termination: Dual 0.250" (6.35 mm) quick connects. Arc Cover: Optional on 20-30 FLA models, standard on 40 FLA models. Weight: One Pole Types: 8 oz. (227 g) approximately. Two Pole Types: 9.6 oz. (273 g) approximately
Coil Data @ 25C
Voltage: 24 - 277 VAC, 50/60 Hz. See Coil Data Table below. Insulation Class: UL Class B (130C). Duty Cycle: Continuous.
Contact Ratings
Full Load Amps 20 Number of Poles 2 Line Voltage 240/277 480 600 240/277 480 600 240/277 480 600 240/277 480 600 240/277 480 600 240/277 480 600 240/277 480 600 Locked Rotor Amps 120 100 80 150 50 40 150 125 100 150 75 50 150 125 100 240 200 160 240 200 160 Resistive Amps Rating 30 30 30 30 30 30 35 35 35 40 40 40 40 40 40 50 50 50 50 50 50 Maximum Horsepower Voltage Single Phase 120 2 240 3 120 240 120 240 120 240 120 240 120 240 120 240 1 2 2 3 1 2 2 3 2 3 2 3
25
1
25
2
30
1
30
2
40
1
40
2
Coil Data
Nominal Coil Voltage Maximum Pickup Volts Drop-Out Volts Range Nominal Inrush VA @ 50 Hz Nominal Inrush VA @ 60 Hz Nominal Sealed VA @ 50 Hz Nominal Sealed VA @ 60 Hz Nominal DC Resistance - Ohms Dimensions are shown for 24 18 6 - 15 22.5 20 7 5.25 16.5 1-Pole Models 120 88 20 - 70 22.5 20 7 5.25 420 208/240 177 40 - 140 22.5 20 7 5.25 1850 277 221 50 - 165 22.5 20 7 5.25 2650 24 18 6 - 15 37 35 8 7 11 2-Pole Models 120 88 20 - 70 37 35 8 7 250 208/240 177 40 - 140 37 35 8 7 1000 277 221 50 - 165 37 35 8 7 1600
830 reference purposes only.
Dimensions are in inches over (millimeters) unless otherwise specified.
Specifications and availability subject to change.
www.tycoelectronics.com Technical support: Refer to inside back cover.
Catalog 1308242 Issued 3-03
PRODUCTS UNLIMITED
Ordering Information
Typical Part No.
B
3100
-
20
Q
6
999
1. Series: 3100 = 1- or 2-pole, 20-40 FLA contactor 2.Packaging: Y = Individual Pack - = Bulk Pack A-ZZZ = Customer specific information (assigned by factory) 3.Pole Configuration: 10 = 1 Form X (SPST-NO-DM) 15 = 1 Form X (SPST-NO-DM) with Shunt 20 = 2 Form X (DPST-NO-DM) 4.Coil Voltage (50/60 Hz.): Q = 24VAC T = 120VAC U = 208/240VAC P = 100VAC S = 200VAC V = 277VAC 5.Contact Ratings (Inductive): 1 = 25 FLA on 1-pole models 3 = 20 FLA on 2-pole models 2 = 30 FLA on 1-pole models 5 = 26 FLA on 2-pole models 14 = 35 FLA on 1-pole models 6 = 30 FLA on 2-pole models 19 - 40 FLA on 1-pole models 18 = 40 FLA on 2-pole models 6.Customer ID Suffix: 999 = Standard Model 000-998 = Factory assigned customer ID 7. Option Code: Leave Blank = No customer-specific options A - ZZ = Factory assigned customer-specific options.
Standard part numbers listed below are more likely to be available from stock.
3100-15Q2999 3100-15T2999 3100-15U2999 3100-20Q6999 3100-20T6999 3100-20U6999 3100-20Q18999CL 3100-20T18999CL 3100-20U18999CL
Outline Dimensions
1-Pole
2.10 Max. (53.3)
Termination Options
.253 (6.43) 3.30 (83.8) 1.625 .875 (41.28) (22.2)
2.313 (57 .75)
2.445 (62.1)
1.625 (41.3) 2.00 (50.8) 2.541 (64.5)
.215 TYP (5.46)
Standard on 20, 25, 30, 35 FLA #10-32 Combination Phillips, Slotted & 5/16 Hex Head #12 Washer
Special on 20, 25, 30, 35 FLA #10-32 Sems Screw with Pressure Plate
Standard on 40 FLA Lug accepts 14-4 Cu/Al AWG
2-Pole
2.10 Max. (53.3)
3.30 (83.8)
2.313 (57 .75)
1.625 .875 (41.28) (22.2)
2.445 (62.1)
1.625 (41.3) 2.00 (50.8) 2.610 (66.3)
.215 TYP (5.46)
ORDERING NOTE: "Standard" terminals need not be specified in the "Ordering Information" chart above. "Special" terminals are offered on a special order basis. Special order items may be subject to extended leadtimes and significant minimum order quantities. Your Tyco Electronics sales engineer must consult with the factory before providing price and availability information regarding items with these options.
Dimensions are shown for reference purposes only.
Dimensions are in inches over (millimeters) unless otherwise specified.
Specifications and availability subject to change.
www.tycoelectronics.com Technical support: Refer to inside back cover.
831


▲Up To Search▲   

 
Price & Availability of 3100-15V14999

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X